OBD:BINA/OBJC/TRGV
< OBD:BINA | OBJC(Redirected from OBD:BINA/Trigger Volume)
Jump to navigation
Jump to search
|
Offset | Type | Raw Hex | Value | Description |
---|---|---|---|---|
0x000 | char[4] | 43 4A 42 4F | OBJC | objects |
0x004 | int32 | 7C 33 00 00 | 13180 | size of the complete neutral part from this position in bytes |
0x008 | int32 | 27 00 00 00 | 39 | object list version |
0x00C | int32 | 60 01 00 00 | 352 | size of the following object in bytes |
First object (grey outline | ||||
0x000 | char[4] | 56 47 52 54 | TRGV | trigger volume (TV) |
0x004 | int32 | ED 1B 00 00 | 7149 | old file ID |
0x008 | int32 | 00 00 00 00 | 0 | unknown |
0x00C | float | 5C 47 36 44 | 729.114990 | x-position of TV |
0x010 | float | 00 00 00 00 | 0.000000 | y-position (height) of TV |
0x014 | float | 73 D8 C9 C3 | -403.691009 | z-position of TV |
0x018 | float | 00 00 00 00 | 0.000000 | rotation on the x-axis in degrees |
0x01C | float | 00 00 00 00 | 0.000000 | rotation on the y-axis in degrees |
0x020 | float | 00 00 00 00 | 0.000000 | rotation on the z-axis in degrees |
0x024 | char[63] | trigger_volume_01 | name of TV | |
0x063 | char[32] | spawn_floor2_guards | "entry" function; called up when character enters the TV | |
0x083 | char[32] | unused | "inside" function; called while character is inside the TV | |
0x0A3 | char[32] | unused | "exit" function; called up when character leaves the TV | |
0x0C3 | bitset | 01 | 1 | teams that can fire off the TV; any combination of the following:
|
0x0C4 | int24 | FF FF FF | unknown | always the same; probably padding |
0x0C7 | float | 00 00 F8 41 | 31.000000 | x-dimension of the TV |
0x0CB | float | 00 00 4C 42 | 51.000000 | y-dimension of the TV |
0x0CF | float | 00 00 08 42 | 34.000000 | z-dimension of the TV |
0x0D3 | int32 | 01 00 00 00 | 1 | trigger volume ID |
0x0D7 | int32 | 00 00 00 00 | 0 | trigger volume ID of the parent TV, if this one is a child |
0x0DB | char[128] | unused | space for notes | |
0x15B | int32 | 81 00 00 00 | 0x80 + 0x01 | flags; any combination of the following:
|
0x15F | 00 | 0 | padding |
- Resetting the trigger volume
- trigvolume_reset(string tv_name) resets the TV to its preset state. The primary use of this is to re-enable "entry", "inside" or "exit" calls once the TV has been triggered (only necessary if the respective trigger-only-once flags are set of course). Note that some or all the TV functions are disabled at level load, you'll have to enable them manually after resetting the TV.
- "Inside" event
- This one is triggered at every frame (60 times per second) unless the trigger-only-once flag is set. Continuous triggering is typically needed for fire or gas damage.
- Tool Mode dialog
ONI BINARY DATA |
---|
AKVA << Other file types >> CBPI |
BINA : Binary data |
TMBD << Other BINA >> ONIE |
OBJC : Objects |
SNDG << Other OBJC >> TRIG |
TRGV : Trigger Volume |
Level file |