XML:BINA/OBJC/TRIG
Jump to navigation
Jump to search
Offset | Type | Raw Hex | Value | Description |
---|---|---|---|---|
0x75 | int16 | 00 00 | 0 | time of interruption interval in frames |
0x77 | int16 | 00 00 | 0 | time of interruption in frames |
Dox, could you explain the effect of these two fields in more detail? The current description is not clear enough. --geyser 20:03, 27 October 2008 (CET)
Okay, here's a fully example. When you set 360 (at 0x75) and 120 (at 0x77) then the laser get disabled after 6 seconds for 2 seconds, then it loops. --Paradox-01 21:42, 27 October 2008 (CET)